Products Finishing Directory

AUTOMATED FINISHING SYSTEMS
Simultaneous engineering reduces energy and resource consumption.
Timothy J. Kurcz, Director of Sales

Reprinted from the 2016, PRODUCTS FINISHING DIRECTORY and Copyright © 2015 by Gardner Business Media, Inc.,
6915 Valley Ave., Cincinnati, Ohio 45244-3029.

Products Finishing Directory PDF


Finishing system operators can deliver repeatable quality with reduced labor and improve profitability by installing properly sized, resource-efficient plating and/or coating systems. This is accomplished by simultaneous engineering of tank, hoist and labor limits to achieve specific quality and productivity requirements. Development requires precise knowledge of current and future throughput requirements, your chemistry supplier’s process sequence, including all process and rinse baths with immersion times, temperatures, and work package selection (rack, basket or barrel). These requirements must be coupled with efficient material handling to complement load/ unload labor.

With throughput, work package, and a process sequence well defined, external limitations such as ceiling height, floor space, chemistry-specific area/volume ratios, and/or rectifier amp-square-foot (ASF) requirements can be considered. Together, they influence hoist capacity, loads per hour and the number of process cells required.

Figure 1. Rack plating.
Figure 1. Rack plating.

For rack electroplating, your chemistry supplier will recom­mend inter-part spacing needed to optimize throwing power, typically 1.5 to 2.5 times the part diameter or width (Fig. 1). Coating racks are not bound by such limitations, and may be densely packed provided parts don’t touch. Spacing must be known early in the process to determine rack density (stated as parts per square foot) to assure repeatable quality. Throughput is a function of parts per rack times loads per hour. It is the primary driver for development of the three-dimensional work package, stated as width × height × direction-of-travel (DOT). Maximum part load, together with the rack and carrier bar weight determine hoist capacity.

Barrel work is metered in pounds to meet surface area fill for electroplating, or volume fill for electroless coating (Fig. 2). Time-to-plate is slower for barrels compared with racks, where throwing power is limited by perforation size, percentage of open space, and part surface area exposed to anodes. Coating barrels are not so limited: Barrel fills are typically 33 percent for plating and 80 percent for coatings by volume. Be aware there exists an inverse relationship between part size and packing density. Example: The packing density (stated as parts per cubic foot) for ¼-inch diameter by ½-inch-long fasteners includes a significantly higher count and surface area than the packing density of a cubic foot of ½-inch diameter by 4-inch-long fasteners. Surface area, weight and packing density must be known for each part early in the machine development process. The three dimensional barrel work package is stated as diameter × width (or length) from which volume fill is calcu­lated. The barrel, super structure, and maximum designed parts fill determine hoist capacity.

Figure 2. Barrel plating.
Figure 2. Barrel plating.

Tank dimensions are dictated by the work package size, and vary depending on content such as heating/cooling elements, ultrasonic transducers, spargers, eductors, agitation devices and tank monitoring sensors. Circulation pumps and filters are sized based on turns per hour defined as the number of gallons per tank times turns; a value wholly dependent on tank volume. Heating and/or cooling requirements are dependent upon bath temperature and immersed work package mass times loads per hour. Together, they determine thermal loading and boiler and/ or chiller size. The American Council of Governmental Industrial Hygienists dictates ventilation and scrubber type based on tank surface area, chemistry type, concentration and temperature.

Only after these basics are established can resource-saving machine features be considered. One of the single greatest opportunities is to limit tank surface area, which reduces evapo­rative, thermal and floor space consumption. In general, wider, taller work packages with shortest possible DOT will deliver the most efficient use of labor, energy, chemistry, water and space. Furthermore, finishing systems make best use of resources when run ’round the clock. It should now be evident why simulta­neous engineering is required. Specific resource management technologies will now be considered.

Computer Driven Automation

Computer controls automatically monitor, store and export load-by-load quality data for immersion times, tank tempera­tures, rectifier settings, chemistry adds, rinse water replen­ishment, barrel rotation/oscillation, ventilation/air makeup, wastewater treatment, and more (Fig. 3). The goal is to install advanced machine features with complimentary controls to enable precise resource management, reduce operator input errors (and corrective actions), and eliminate manual quality monitoring/reporting to further reduce labor cost.

Figure 3. Computer controls automatically monitor, store and export loadby- load quality data for immersion times, tank temperatures, rectifier settings, chemistry adds, rinse water replenishment, barrel rotation/ oscillation, ventilation/air makeup, wastewater treatment, and more.
Figure 3. Computer controls automatically monitor, store and export load by-load quality data for immersion times, tank temperatures, rectifier settings, chemistry adds, rinse water replenishment, barrel rotation/oscillation, ventilation/air makeup, wastewater treatment, and more.
Recipe driven individual plate cell rectification enables precise, repeatable plate thickness for every load regardless of part count for rack plating, or by weight for barrel plating. Bar code loaded recipes enable the computer to calculate surface area on a discreet part number basis, and adjust process param­eters accordingly. Manual or automatically entered rack part count assures precise ASF delivery. Barrel weight is automati­cally verified by load cells during the fill operation, likewise assuring precise ASF delivery.

High-efficiency, VFD-controlled hoist motor/drive combi­nations guided with absolute linear encoders provide the smoothest possible motion profiles, eliminate rack or barrel shake, reduce motor brake wear and reduce electrical energy consumption. Corrosion-proof belt lifts reduce drag and dramatically extend maintenance intervals. Integration of these features significantly reduces operation and maintenance costs.

Water & Chemistry Reduction

Figure 4. Cylindrical plating (and coating) barrels offer a 17 percent increase in volume and more consistent anode-to-work relationship compared to hex style barrels of the same size.
Figure 4. Cylindrical plating (and coating) barrels offer a 17 percent increase in volume and more consistent anode-to-work relationship compared to hex style barrels of the same size.

Given today’s pressure to conserve earthly resources, it’s prudent to make efficient use of water and chemistry to the greatest extent possible. Advanced fluid management devices and controls can dramatically reduce consumption of both.

Load-by-load rinse water replenishment can optimize water consumption on a recipe-driven basis if desired. The ultimate goal is to reduce process water usage, which in turn reduces wastewater treatment loading and its associated chemistry. Load-by-load recipe-driven chemistry addition eliminates saw-tooth fluctuations common with less frequent additions. An integrated PC/ HMI is needed to recognize and select recipes, and adjust for rack or barrel fill variation. Ethernet based controls allow local or remote replenishment adjustments any time during machine operation.

Your chemistry supplier may recommend RO water due to unsuitable local water quality, or it may be required for a specific process chem­istry. RO equipment requires floor space, energy, and water (appx. 30 percent rejection rate). Makeup, addition, and/ or replenishment for evapora­tive losses may be partially or completely accomplished with dragout recovery, further reducing the need for fresh or RO water.

Careful consideration should be given to plating and coating barrel design. Cylindrical plating (and coating) barrels offer a 17 percent increase in volume and more consistent anode-to-work relationship compared to hex style barrels of the same size (Fig. 4). Perforation size and shape greatly affect time to drain. Finally, up-barrel rotation drains directly to the process tank reducing carryover, a feature especially important for parts known to cup solution. Up-barrel rotation should be considered mandatory in today’s demanding parts finishing environment.

Wastewater Treatment Basics

Figure 5. Computer controlled wastewater treatment systems manage rinse waters, process tank dumps and treatment resources with precision. Image courtesy of J. Mark Systems.
Figure 5. Computer controlled wastewater treatment systems manage rinse waters, process tank dumps and treatment resources with precision. Image courtesy of J. Mark Systems.

Critical to resource reduction strategy is a basic understanding of water consumption drivers. Water use begins with total purchased and ends the total water discharged, a variable expense that directly affects operating cost. Computer controlled wastewater treatment systems manage rinse waters, process tank dumps and treatment resources with precision (Fig. 5).

Wastewater treatment sizing is almost purely a function of part surface area. Water treatment experts find one gallon of dragout is generated for every 1,000 square feet of surface area processed, and that each gallon of dragout requires approxi­mately 600 gallons of rinse water to maintain process quality. Fortunately, most parts are designed in CAD today, so area and water consumption can easily be calculated.

To minimize wastewater treatment demand, machines should be designed to reduce dragout and carryover by every means possible. Opportunities include quick draining rack, barrel or basket designs with increased drain dwells and/or program­mable drip trays. Tipping, tilting, or vertical oscillation for racks; optimized perforations with up-rotation for barrels dramatically reduce dragout/carryover. Recirculating spray pre-clean tanks, multiple soak clean tanks, two rinses minimum between baths, or three between alkaline and acid chemistry, and top sprays are features that reduce dragout and carryover losses.

Ventilation & Air Makeup Management

Figure 6. Machine enclosures can reduce total volume of ventilation air required and reduce or eliminate the effect of transient air flows, which otherwise adversely affect push-pull ventilation systems.
Figure 6. Machine enclosures can reduce total volume of ventilation air required and reduce or eliminate the effect of transient air flows, which otherwise adversely affect push-pull ventilation systems.

Variable frequency drive (VFD) ventilation blower motor controls can slave ventilation speed to tank temperatures. This offers the opportunity to slow ventilation output as tanks cool during overnight or weekend shutdowns. Additional savings can be achieved if VFD controls are added to air makeup system blowers for integration with the ventilation system. Machine enclosures can reduce total volume of ventilation air required and reduce or eliminate the effect of transient air flows, which otherwise adversely affect push-pull ventilation systems (Fig. 6). Operator safety is improved because the ventilation barrier is located between the catwalk and automation.

Control, Monitoring, Recording, Reporting

PC/HMI operation of finishing systems should be considered standard for all finishing systems. NADCAP & ISO compliance is assured if the machine is equipped with appropriate sensor technology. Data such as tank temperatures, immersion times, rectification, pH, conductivity, rotation/oscillation speed and/ or duration, chemistry and water additions, drain dwells, and dryer temps are collected, stored, and exported to the customer database for analysis and report generation.

From an operational standpoint, engineered process cycles offer the most efficient production performance, though mixed processes with variable plate time cycles are available at the cost of some productivity. Most operators prefer fixed production rates so load/unload operations and external logistics remain unaffected.

For ease of management, performance monitoring may include shift reports for total time and number of cycles run, tracking of automatic versus manual operation, load/unload delays, and fault data.

To speed correction of unexpected stoppages, a well- designed control system will provide automatic system diagnostics. Detailed screens should display fault location and actions needed to quickly restore production. Internet-based remote monitoring further expedites troubleshooting and repairs.

Regardless of operational strategy, machine operation must be simple and intuitive. A user-friendly, multi-lingual, touch screen human machine interface is a necessity in today’s finishing environment. An industrial PC with Windows-based software enables easy PLC interface without the need for a programmer.


About Jessup Engineering
Jessup Engineering is the leading manufacturer of automatic hoists, controls, and turn-key finishing systems in North America, with more than 690 machines and 1,370 hoists installed in 45 years. Programmable hoists offer the most flexible, efficient, and reliable motion control for plating, anodizing, phosphate, e-coat, FPI inspection, and more. Jessup controls monitor, record, and export data for every machine function, ensuring ISO and NADCAP compliance. Implementation of energy and resource reduction methods makes Jessup machines some of the most efficient in the industry. To learn more about Jessup finishing system, please visit www.jessupengineering.com and call 248-853-5600.

About the Author
Timothy J. Kurcz, Director of Sales for Jessup Engineering, has been in the surface engineering community for 40 years. His experience includes process automation for adhesives, sealants, coatings, electro- and electro-less plating, cleaning, passivation, E-coat, A-coat coatings, and Florescent Penetrant Inspection. Mr. Kurcz can be reach d at 248-853-5600 or via e-mail at tkurcz@jessupengineering.com